Welcome to Asees Renovation

Experts in Side Entrances, Egress Windows & Concrete Cutting

Below Grade Side Entrances

Expertly built below-grade entrances designed for safe, legal, and convenient basement access.

Above Grade Side Entrances

Quality above-grade entrances built to enhance accessibility, safety, and home value.

Egress Windows Installation

Professional egress window installation ensuring safety, natural light, and full Ontario Building Code compliance.

Concrete Sidewalk

Durable and seamless concrete sidewalks crafted for long-lasting curb appeal and functionality.

Concrete & Brick Wall Cutting

Precision cutting for concrete or brick walls using advanced equipment for clean, accurate openings.

Concrete Driveway

Strong, smooth, and weather-resistant concrete driveways designed to last for decades.

Following the Ontario Building Code (OBC)

General Code Compliance

  • All openings (windows, doors, entrances) are constructed under a valid building permit.

  • Structural integrity is reviewed before cutting or altering load-bearing walls.

  • Proper lintels and supports are installed above all new openings.

  • Drainage, grading, and waterproofing meet OBC Part 9 (residential construction) standards.

  • Energy efficiency and insulation requirements are met for new openings or walls.

  • Fire separation and smoke protection are maintained between dwelling units as required.

Below-Grade Side Entrance Requirements

  • Minimum ceiling height and stair dimensions follow OBC Section 9.8.

  • Proper drainage and sump system installed at the bottom of the stairwell.

  • Exterior door threshold kept at least 2″ above finished drain surface.

  • Retaining walls and window wells are structurally reinforced.

  • Non-slip stairs and guardrails/handrails provided per OBC safety standards.

  • Fire-rated door if accessing a secondary suite.

Above-Grade Side Entrance Requirements

  • Proper framing and header support when cutting into a structural wall.

  • Minimum clear width and height for entry doors per OBC Section 9.7.

  • Landing size and step configuration comply with OBC requirements.

  • Weatherproof flashing and insulation added to prevent air and moisture infiltration.

Egress Window Requirements

  • Compliant with OBC Section 9.9.10.1 – Emergency Egress.

  • Minimum unobstructed opening: 3.77 sq. ft (0.35 m²).

  • Minimum opening dimension: 15″ (380 mm) in any direction.

  • Window well clearance: Minimum 22″ (550 mm) in front of window.

  • Window must be openable without tools or keys.

  • Drainage at the bottom of window wells to prevent water accumulation.

Concrete or Brick Cutting Requirements

  • Structural assessment before cutting to ensure load-bearing stability.

  • Steel lintels or concrete headers installed as required.

  • Reinforcement and sealing to prevent water penetration.

  • Dust control and noise reduction measures during cutting.

  • All cuts are inspected for alignment and integrity before finishing.

Permit & Inspection Coordination

  • We assist with permit drawings and engineering approvals.

  • All work is inspected by city building officials at key stages.

  • Final completion ensures full OBC and municipal compliance certification.

We’ve Been Building For Over 4 years

Let’s Create Your Perfect Space!

Address: 118 Viceroy Crescent, Brampton, ON – L7A 1V4

Phone: +1 437-522-1112

Email: jaskaransidhu55148@gmail.com

Locations we serve: Mississauga, Oakville, Burlington, Waterdown, Milton, Stoney Creek, Hamilton, Ajax, Whithby, Guelph, Kitchener, Cambridge, Brantford, St.Catharines, and Niagara Falls

Contact Us Form

Select your Option

12 + 3 =

We’d like to occasionally send you messages about Asees Renovation programs, events, and special offers using your preferred methods.
You will always have an option to optout using the ‘unsubscribe’ option in the messages you receive.